Contact Us
0086-411-88014357
0086-411-88014357
China (Liaoning) Pilot Free Trade Zone Dalian Economic and Technology Zone Shengming 3rd Road No.27
MUF-2000F2 Series Integral

Integral ultrasonic flow meter (MUF-2000F2)

Item No.: 26
MUF-2000F2 Ultrasonic Flow Meter is designed to measure the fluid velocity of liquid in a full or closed pipe. This model is inline measurement with various kinds of sensors.
INQUIRY
Description Specifications Sensor Type Installation

MUF-2000F2 Ultrasonic Flow Meter is designed to measure the fluid velocity of liquid in a full or closed pipe. This model is inline measurement with various kinds of sensors. Inline type ultrasonic flow meter has the advantages of low starting flow rate, high measurement accuracy, no pressure loss etc.
 
  • Measures energy consumption rate and total
  • Compact inline version
  • Proven ultrasonic technology for flow measurement and reliable PT 100 RTDs for temperature measurement
  • Wide range of fluid velocities - 0 ~ ± 7 m/sec.
  • Transducers for pipe sizes ranging from ½" to 240" (15 to 6000 mm)
  • High accuracy - ±1.0% of reading
  • RS485 and Modbus communication protocols available
  • 4-20 mA and pulse outputs with available relays and alarms
  • Data logger function - includes time & date, totalizer, diagnostics
  • Fast response time - less than 1 second
  • IP68 protection

 
 
Principle Ultrasonic time difference principle
Accuracy
  • Inline type:   Flow meter ±0.5%  Heat meter ±1.0%
  • Clamp on type: Flow meter ±1.0%  Heat meter ±2.0%
  • Insertion type: Flow meter ±1.0%  Heat meter ±2.0%
Operation Support 4 keyboards magnetic bar/4 touch keyboards/simulation keyboard software
Signal output
  • 1 way 4-20mA, electric resistance 0-1K, accuracy 0.1%
  • 1 way OCT pulse output (pulse width 6-1000ms, default is 200ms)
  • 1 way relay output
Signal input 3 way 4-20mA input, accuracy 0.1%, acquisition signal such as temp, pressure and liquid level
Connect the temperature sensor PT100 for the heat and energy measurement
Communication Insulate RS485, support Modbus
Special cable
  • Twisted-pair cable, generally the length below50m
  • Select the RS485, transmission distance can be over 1000m
Pipe
installation condition
  • Pipe material: Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed.
  • Pipe diameter: 15-6000mm
  • Straight pipe: upstream 10D, downstream 5D, 30D from the pump
Measuring medium Single liquid can transmit sound wave, turbidity is no more than 10000ppm and less bubble, flow rate is 0~±10m/s, such as
  • Water (hot water, chilled water, city water, sea water, waste water)
  • Sewage with small particle content
  • Oil (crude oil, lubricating oil, fuel oil, etc)
  • Chemicals like alcohol
  • Plant effluent
  • Beverage
Medium temp Sensor: -30~+90deg C (standard), -30~+160deg C (option)
Ambient condition Ambient temperature for converter: -20~+60deg C
Humidity: Converter 85%RH
Power supply 8-36VDC or 85-264VAC
Power consumption 1.5W
Protection IP68


 

Optional Sensor


Optional temperature sensor



 
     
     
Clamp-on type
Pipe size DN15-DN6000
Insertion type
Pipe size DN80-DN6000
Π type
Pipe size DN15-DN32
Flange type
Pipe size DN50-DN1000